top of page
Codi's logo

Low-Voltage Switchgear

SWITCHBOARD

UL 891 Listed · Dead-Front · NEMA 1 / 3R

The CODI UL 891 Switchboard is an engineer-to-order, dead-front distribution assembly built for main service entrance, main distribution, and emergency power applications across commercial, industrial, and mission-critical facilities. Each unit is code-compliant and configured to your project's voltage, ampacity, fault current rating, breaker brand. Independently manufactured in Littleton, Colorado with full UL 891 listing, complete engineering documentation, and shorter lead times than national OEMs.

400A–6000A

120/208V–347/600V

200kAIC

Custom UL 891 dead-front switchboards for main service, distribution, and emergency power applications. Configurable ampacity, fault current ratings, and multi-brand breaker flexibility. Shorter lead times than national OEMs. Built in Littleton, Colorado.

400A–6000A

120/208V–347/600V

200kAIC

6-10

WEEK LEAD TIME

KEY FEATURES

Custom Configuration

Engineered to your project's exact voltage, ampacity, fault current, and breaker requirements — not a catalog solution.

UL 891 Listed Dead-Front

Every switchboard ships UL 891 listed as a dead-front assembly, preventing access to live bus and components during normal operation.

High-Capacity Bus

Main bus ratings from 400A to 6000A; silver-plated copper or tin-plated aluminum bus available.

High Fault Current Ratings

Short-Circuit Current Ratings (SCCR) up to 200kAIC to match facility fault current requirements.

Multi-Brand Breaker Compatibility

Accommodates molded-case and insulated-case circuit breakers from major manufacturers (Siemens, Eaton, ABB, etc.) — no proprietary lock-in.

Enclosure Options

TYPE 1 (indoor) and TYPE 3R (outdoor) configurations; stainless steel available for corrosive environments.

FULL SPECIFCATIONS

    • Applicable Standard: UL 891 – Dead-Front Switchboards 

    • Applicable Codes: NEC (ANSI/NFPA 70); CSA C22.2 No. 244 (Canada, when applicable) 

    • Maximum Voltage Rating: Up to 600 V AC nominal (maximum 1,000 V within UL scope) 

    • Intended Application: Commercial and Light Industrial Power Distribution

    • Input Voltages Available: 120/208 V, 240 V, 480/277 V, 600/347 V AC 

    • Frequency: 60 Hz 

    • Main Bus Ampere Rating: 400 A – 6,000 A (higher ratings available by design) 

    • Short-Circuit Current Rating (SCCR): Up to 200 kAIC at specified voltage 

    • Short-Time Withstand: 3-cycle withstand (0.05 seconds)

    • Construction: Dead-front per UL 891

    • Enclosure: Galvannealed steel with powder-coat or stainless steel finish

    • Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)

    • Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7

    • Mounting: Free-standing configurations standard; wall-mount availability dependent on ampacity and breaker frame size

    • Access: Padlockable front doors with three-point latching

    • Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination

    • Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available

    • Protective Devices: Molded-case or insulated-case circuit breakers

    • SCCR: Rated and marked per UL 891 to project-specific short circuit current requirements

    • Trip Settings: LSI and LSIG configurations available

    • Arc-Flash Risk Reduction: Energy-reducing maintenance settings per NFPA 70 240.87; compatible with AERMS, DAS (Siemens), and RELT (ABB)

    • Zone-Selective Interlocking: Available where applicable

    • Ground Fault Protection: Per NFPA 70B

    • Thermal Inspection: Compliance-ready designs for routine infrared inspection

    • Custom Configuration: Engineered to your project's exact voltage, ampacity, fault current, and breaker requirements — not a catalog solution.

    •  UL 891 Listed Dead-Front: Every switchboard ships UL 891 listed as a dead-front assembly, preventing access to live bus and components during normal operation.

    •  High-Capacity Bus: Main bus ratings from 400A to 6000A; silver-plated copper or tin-plated aluminum bus available.

    •  High Fault Current Ratings: Short-Circuit Current Ratings (SCCR) up to 200kAIC to match facility fault current requirements.

    • Multi-Brand Breaker Compatibility: Accommodates molded-case and insulated-case circuit breakers from major manufacturers (Siemens, Eaton, ABB, etc.) — no proprietary lock-in.

    • Wide Voltage Range: Configurable for 120/208V, 277/480V, and 347/600V 3-phase AC systems.

    • Service Entrance Rated (SE): Optional Service Entrance rating allows the unit to serve as the primary disconnect per NEC 230.

    • Metering and Instrumentation: Optional revenue-grade metering, current transformers, and digital power meters available for energy management.

    • Ground Fault Protection: Optional Ground Fault Protection of Equipment (GFPE) per NEC 230.95 available on service entrance configurations.

    •  Arc-Flash Risk Reduction: Energy Reducing Maintenance Settings (ERMS) and zone-selective interlocking (ZSI) available. NFPA 70B Compliance-ready Designs for Routine Thermal Inspection

    •  Enclosure Options: TYPE 1 (indoor) and TYPE 3R (outdoor) configurations; stainless steel available for corrosive environments.

    •  MADE IN THE USA: Engineered and assembled in Littleton, Colorado for faster lead times and direct manufacturer support.

RESOURCES

Future: test White Paper
this section will be built out once we have more documentation.
this section will be built out once we have more documentation.

VIDEO

BUILT THE CODI WAY

STRUCTURAL ENGINEERING

  • Hex-Formed Corners

  • Powder coating in any color

  • Internal cable routing pathways

  • Tab & slot nest together precisely

MANUFACTURING EXCELLENCE

  • Shorter lead-times than national OEMs

  • Ships right the first time

  • 30 years of fabrication experience

  • 100k sq.ft. Littleton, CO facility

OEM BREAKER FLEXIBILITY

  • Matches your existing infrastructure specs

  • No proprietary lock-in

  • Access to multiple OEM breaker brands

STREAMLINED ORDER PROCESS

  • Online configuration tool

  • Quotes reviewed in-house - typically within 1 business day 

READY TO SPEC YOUR SWITCHBOARD?

EXPLORE OTHER PRODUCTS

bottom of page