Low-Voltage Switchgear
SWITCHBOARD
UL 891 Listed · Dead-Front · NEMA 1 / 3R
The CODI UL 891 Switchboard is an engineer-to-order, dead-front distribution assembly built for main service entrance, main distribution, and emergency power applications across commercial, industrial, and mission-critical facilities. Each unit is code-compliant and configured to your project's voltage, ampacity, fault current rating, breaker brand. Independently manufactured in Littleton, Colorado with full UL 891 listing, complete engineering documentation, and shorter lead times than national OEMs.
400A–6000A
120/208V–347/600V
200kAIC
Custom UL 891 dead-front switchboards for main service, distribution, and emergency power applications. Configurable ampacity, fault current ratings, and multi-brand breaker flexibility. Shorter lead times than national OEMs. Built in Littleton, Colorado.
400A–6000A
120/208V–347/600V
200kAIC
6-10
WEEK LEAD TIME
KEY FEATURES
Custom Configuration
Engineered to your project's exact voltage, ampacity, fault current, and breaker requirements — not a catalog solution.
UL 891 Listed Dead-Front
Every switchboard ships UL 891 listed as a dead-front assembly, preventing access to live bus and components during normal operation.
High-Capacity Bus
Main bus ratings from 400A to 6000A; silver-plated copper or tin-plated aluminum bus available.
High Fault Current Ratings
Short-Circuit Current Ratings (SCCR) up to 200kAIC to match facility fault current requirements.
Multi-Brand Breaker Compatibility
Accommodates molded-case and insulated-case circuit breakers from major manufacturers (Siemens, Eaton, ABB, etc.) — no proprietary lock-in.
Enclosure Options
TYPE 1 (indoor) and TYPE 3R (outdoor) configurations; stainless steel available for corrosive environments.
FULL SPECIFCATIONS
Applicable Standard: UL 891 – Dead-Front Switchboards
Applicable Codes: NEC (ANSI/NFPA 70); CSA C22.2 No. 244 (Canada, when applicable)
Maximum Voltage Rating: Up to 600 V AC nominal (maximum 1,000 V within UL scope)
Intended Application: Commercial and Light Industrial Power Distribution
Input Voltages Available: 120/208 V, 240 V, 480/277 V, 600/347 V AC
Frequency: 60 Hz
Main Bus Ampere Rating: 400 A – 6,000 A (higher ratings available by design)
Short-Circuit Current Rating (SCCR): Up to 200 kAIC at specified voltage
Short-Time Withstand: 3-cycle withstand (0.05 seconds)
Construction: Dead-front per UL 891
Enclosure: Galvannealed steel with powder-coat or stainless steel finish
Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)
Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7
Mounting: Free-standing configurations standard; wall-mount availability dependent on ampacity and breaker frame size
Access: Padlockable front doors with three-point latching
Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination
Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available
Protective Devices: Molded-case or insulated-case circuit breakers
SCCR: Rated and marked per UL 891 to project-specific short circuit current requirements
Trip Settings: LSI and LSIG configurations available
Arc-Flash Risk Reduction: Energy-reducing maintenance settings per NFPA 70 240.87; compatible with AERMS, DAS (Siemens), and RELT (ABB)
Zone-Selective Interlocking: Available where applicable
Ground Fault Protection: Per NFPA 70B
Thermal Inspection: Compliance-ready designs for routine infrared inspection
Custom Configuration: Engineered to your project's exact voltage, ampacity, fault current, and breaker requirements — not a catalog solution.
UL 891 Listed Dead-Front: Every switchboard ships UL 891 listed as a dead-front assembly, preventing access to live bus and components during normal operation.
High-Capacity Bus: Main bus ratings from 400A to 6000A; silver-plated copper or tin-plated aluminum bus available.
High Fault Current Ratings: Short-Circuit Current Ratings (SCCR) up to 200kAIC to match facility fault current requirements.
Multi-Brand Breaker Compatibility: Accommodates molded-case and insulated-case circuit breakers from major manufacturers (Siemens, Eaton, ABB, etc.) — no proprietary lock-in.
Wide Voltage Range: Configurable for 120/208V, 277/480V, and 347/600V 3-phase AC systems.
Service Entrance Rated (SE): Optional Service Entrance rating allows the unit to serve as the primary disconnect per NEC 230.
Metering and Instrumentation: Optional revenue-grade metering, current transformers, and digital power meters available for energy management.
Ground Fault Protection: Optional Ground Fault Protection of Equipment (GFPE) per NEC 230.95 available on service entrance configurations.
Arc-Flash Risk Reduction: Energy Reducing Maintenance Settings (ERMS) and zone-selective interlocking (ZSI) available. NFPA 70B Compliance-ready Designs for Routine Thermal Inspection
Enclosure Options: TYPE 1 (indoor) and TYPE 3R (outdoor) configurations; stainless steel available for corrosive environments.
MADE IN THE USA: Engineered and assembled in Littleton, Colorado for faster lead times and direct manufacturer support.
RESOURCES
Future: test White Paper
this section will be built out once we have more documentation.
this section will be built out once we have more documentation.
VIDEO
BUILT THE CODI WAY
STRUCTURAL ENGINEERING
-
Hex-Formed Corners
-
Powder coating in any color
-
Internal cable routing pathways
-
Tab & slot nest together precisely
MANUFACTURING EXCELLENCE
-
Shorter lead-times than national OEMs
-
Ships right the first time
-
30 years of fabrication experience
-
100k sq.ft. Littleton, CO facility
OEM BREAKER FLEXIBILITY
-
Matches your existing infrastructure specs
-
No proprietary lock-in
-
Access to multiple OEM breaker brands
STREAMLINED ORDER PROCESS
-
Online configuration tool
-
Quotes reviewed in-house - typically within 1 business day